Linear tubular solenoids optimized for long strokes

Tubular Solenoids

  • Stroke up to 30mm
  • Holding force up to 80N
  • High life time
  • Pull and push versions
  • Description
  • Good to know

  • Downloads

Tubular solenoids - for long strokes

Tubular solenoids offer a relatively flat force-displacement characteristic due to their cylindrical shape and the geometry of the plunger. These tubular solenoids, like other linear solenoids, are open/close actuators for opening and closing mechanisms that develop a force in one direction when energized. The restoring force must be provided externally, e.g. via a restoring spring. Tubular solenoids have a service life of more than 30 million cycles and have been optimized especially for long strokes.

1. Design and Features
The tubular solenoids are designed and manufactured to obtain the maximum force output with the minimum of weight and size. Features include a large force output in a small size, minimum flux leakage by design, and a low level of operational noise. The structure consists of a slender cylinder as shown. The outside case is a high permeable steel to improve efficiency. Both pull and push type configurations are available as standard.

2. Stroke and Force
The tubular solenoid is designed for longer strokes than the conical push-pull type solenoid. As such, the pole piece designs are conical to maximize performance over longer strokes. To improve efficiency, the solenoid stroke should be minimized in the application.

3. Operational Considerations
A) Temperature
The coil data for tubular solenoids shows the values at ambient temperature 20°C and with a standard heat sink. If a solenoid is used at the ratings shown in the coil data, it is designed so that the coil temperature rises and reaches equilibrium at approximately 85°C. In applications where the ambient temperature is higher than 20°C or the heat sink is smaller than indicated in the catalog, possible thermal damage can occur.
Temperature rise tests should be performed by the customer to assure that the coil does not reach 120°C. Coils can be constructed to operate at temperatures higher than 120°C without thermal damage. Please consult the factory for details.
B) Air Gap Spacer
The tubular solenoid has an air gap spacer installed between the plunger stopper and the case. This spacer is installed to prevent the plunger and base from coming into mechanical contact with each other, which would cause residual magnetism.
C) Return Spring
The tubular solenoid does not include a return spring. Therefore, the application must include a return spring or modification at the factory.
D) Plunger and Shaft Modifications
It is not recommended that the costumer modify the plunger or shaft, as the shafts are manufactured and plated at the factory. Any special configurations can be supplied. Please consult the factory for details.

4. General Characteristics
Insulation class Class: E (120°C), Lead wire class A (105°C)
Dielectric strength: AC 1000V 50/60 Hz 1 min. (at normal temperature and normal humidity)
Insulation resistance: More than 100 Megohm at DC 500V megger (at normal temperature and normal humidity)
Expected life: Standard life: 2 million cycles, Extended life: 5 million cycles, Long life: 10 million cycles (Solenoid cycle life is very dependent upon side load, frequency of use, and environmental conditions. Cycle life tests should be performed by the customer.)

5. How to Select a Solenoid
Before selecting a tubular solenoid, the following information must be determined:
A) Force
The actual force required in the application should be increased using a safety factor multiplier of 1.5 to arrive at the force value that should be used in your specification.
B) Duty cycle
Use the aforementioned formula to calculate duty cycle. Also note the maximum on time.
C) Stroke
Stroke is determined by application requirements.
D) Operating voltage
Operating DC voltage is determined by application and voltage available.
After determining these specifications, one can find the correct size solenoid for the application, using the force-stroke characteristic tables and graphs. The coil data is also shown for different size of magnet wire. If the exact operating voltage is not in the coil data table, use the nearest voltage shown in the table. NOTE: When the operating voltage falls between 2 coil sizes, always us the higher AWG. numbered coil to prevent potential thermal damage. To determine the force output of the solenoid after temperature rise, please use the amp-turn force graphs after calculating the amp-turns.

6. Ordering Information
When ordering a tubular solenoid, the correct part number needs to be determined from the following combination of characteristics (1-4):
(1) M-Metric Thread or F-SAE Thread
(2) Solenoid Size (example-130)
(3) Coil Wire Number (AWG)
(4) L-Pull, Standard Life,  H-Push, Standard Life,  LE-Pull, Extended Life, HE-Push, Extended Life, LL-Pull, Long Life, HL-Push, Long Life

Article No. Stroke Force 10% ED Force 100% ED Dimensions Feature/Option Images 3D Data sheet Enquiry Wishlist
130 12mm 7N 3N 13x27mm Push and pull versions Enquiry Enquiry
133 3mm 5N 0.9N 13x12mm Push and pull versions Enquiry Enquiry
170 12mm 7N 3.5N 17x27mm Push and pull versions Enquiry Enquiry
190 13mm 18N 8N 19x40mm Push and pull versions Enquiry Enquiry
250 14mm 38N 22N 25x51mm Push and pull versions Enquiry Enquiry
253 12mm 35N 15N 25x30mm Push and pull versions Enquiry Enquiry
320 18mm 70N 35N 32x58mm Push and pull versions Enquiry Enquiry
380 30mm 80N 55N 38x64mm Pull version Enquiry Enquiry